PACKKEEPER / PACKMASTER / PACKLEADER
For inquiries about our products, please use the inquiry form.
PACKKEEPER is low-cost model for O2 measurement only
PACKMASTER is DO-compatible model by using option
PACKLEADER is O2 & CO2 simultaneously measure with one unit
■ One-touch measurements
Just press the START key to begin.
The automatic stability decision function will display the stable value.
Suppose the oxygen sensor fails and becomes unusable within one year of opening the package and starting use. In that case, Iijima Electronics will provide a "fault replacement" so you do not have to purchase an additional sensor for one year. The "fault replacement" is not a new sensor but a product that can be used for the remainder of the warranty term.
1. Pull the oxygen sensor out from the probe.
2. Insert the new oxygen sensor.
3. Mount the probe onto the housing to complete the replacement.
■Clogging detection function
A pressure sensor is mounted. A message will appear if the needle or tube is clogged when the gas is drawn. Replace the part at the site to resolve the problem.
■Guidance display function
Easy-to-understand troubleshooting and error messages are displayed in Japanese. QR Codes are also provided so you can check detailed procedures and videos on our website.
■Memory function (300 cases)
Press the MEMORY key to record the measured values. The history can be read out easily.
Information about operation methods and maintenance.
Product Name Model |
Residual Oxygen Meter PACK KEEPER /RO-105KS |
Residual Oxygen Meter PACKMASTER /RO-105S |
Residual O2/CO2 Meter PACK LEADER /RO-105LS |
Oxygen Sensor | WAGNIT® / Model:WA-SGF2 (One year warranty) |
Oxygen sensor measurement method | Membrane type galvanic cell |
CO2 sensor measurement method |
- | - | NDIR (Non dispersive infrared absorption method) |
Display method | Monochrome TFT LCD display |
O2 measurement range | [Oxygen concentration] 0.00 to 9.99%O2, 10.0 to 85.0%O2 automatic range changeover [Gas replacement rate] 0.0 to 100.0% |
CO2 measurement range |
- | - | 0.0 to 100.0%CO2 |
DO measurement range | - | 0.00 to 9.99mg/L, 10.0 to 20.0mg/L [Saturation rate] 0.0 to 200.0% [Water temperature] 0.0 to 40.0℃ |
- |
Repeatability (Following our measurement conditions at shipment) | O2:[0.00 to 0.99%O2] ±0.03%O2, [1.00 to 9.99%O2] ±0.09%O2 [10.0 to 25.0%O2] ±0.2%O2, [25.1 to 85.0%O2] ±2.0%O2 |
Repeatability (Following our measurement conditions at shipment) |
- | - | CO2:0.0 to 100.0%CO2: ±3% reading value |
Measurement method | One-touch sampling |
Required gas volume | 6mL |
Measurement time | 6 seconds | 6 seconds | 9 seconds |
Calibration method (O2) | Select “CAL” from the menu and press the START key to calibrate. |
Memory function | Up to 300 measurements can be saved. The history can be displayed on the screen. |
External output | - | External connection possible with an RS-232C cable (printer, personal computer) | External connection possible with an RS-232C cable (printer, personal computer) |
Other functions | - Automatic stability decision function (With display function using progress status bar) - Self-diagnosis function (Error message displayed when sensor life is reached or output error occurs, etc.) - Sensor warranty term notification function (Oxygen sensor only) - Clogging detection function - Jappanese/English selection function - Timezone selection function - Guidance display function - Initialization function - Time display function |
Operating temperature range | 5 to 40℃ (With no dew condensation) |
Power supply | AA alkaline batteries or nickel-metal hydride batteries (rechargeable) x 4 batteries, or AC adapter (100VAC) |
Main unit demensions | 93(W) x 155(D) x 125(H) mm (excluding protrusions) |
Main unit weight | Approx. 620g (including batteries) |